Products
Electrochemical Electrodes
- Ion Selective Electrodes
- Silver Metal Electrodes
- Glass pH Electrodes
- Reference Electrodes
- Polarographic Electrodes
- Platinum Electrodes
- Conductivity Cells
- Redox Electrodes
- Dissolved Oxygen Electrodes
- IJ (Intermediate Junction) and IH Electrodes
- SI 20 SCREW-IN pH combination
- CS 41 Combined Sensor
- Temperature Sensors
- Connecting Cables
Accessories and Auxiliary
- Reference and Salt Bridge Solutions
- Ion Standards
- Ionic Strength Adjustors, pH Adjustors, TISAB
- Buffer Solutions
- Heavy Metal Standards
- Conductivity Standards
- Redox Standards
- Storage and Cleaning Solutions
ELMETRON Meters
Declaration of Type Numbers
Product List - Download
Electrochemical Electrodes
Ion Selective Electrodes (ISE)
DPST Ion Selective Electrodes (ISE)
DPST Ion Selective Electrodes (ISE)
ISEs are analytical tools widely used for potentiometric determination of a large scale of ionic analyses, using various procedures of measurement and evaluation. These sensors are especially suitable for routine analysis being done in agriculture and food process, soil analysis, environmental samples, water quality control, tribotechnical analysis, explosives and pyrotechnical mixtures analysis, biochemical and chemical process control and many other applications in research, education and process. DPST Ion selective electrodes fit to all commonly used meters. The work with ion selective electrodes saves time and chemicals and is a friendly priced measuring equipment.
Ion Selective Electrodes, ISE - Product PDF (183 KB)
Silver Metal Electrodes
Silver metal electrodes are sensors for argentometric, coulometric or potentiometric titrations of chloride, bromide, iodide, cyanide, cyanate, sulfocyanide and other ions with slightly soluble silver salts. Our DPST silver metal electrodes are applicable to all commonly used pH-meters, titrators, coulometers and other analytical instruments for argentometric titrations.
Silver Metal Electrodes - Product PDF (44 KB)
Glass pH Electrodes
DPST Glass pH Electrodes
Since a very long period of time, nearly one century, pH glass electrodes are successfully used as sensors for the potentiometric determination of H+, respective H3O+ activity, what is expressed in the well known pH units. pH measurements are essential for all fields of research, development, process and many other human activities.
Glass pH Electrodes - Product PDF (155 KB)
Reference Electrodes
DPST Reference Electrodes
Reference electrodes are commonly used as a stable electric potential source for various electrochemical applications. DPST reference electrodes are applicable to all commonly used electrochemical apparatus.
Reference Electrodes - Product PDF (134 KB)
Polarographic Electrodes
Polarography is an important electrochemical method for many analytical tasks in industrial processes and laboratory research and many other applications. We offer DPST polarographic electrodes as carbon, gold, silver and platinum working electrodes, argentchloride, calomel and mercurosulphate reference electrodes, platinum auxiliary electrodes and a scale of combined electrodes. They are new fashioned, small size compact embodied and very sensitive sensors, widely applied for voltametric analysis of electroactive matters like heavy metals, organic compounds, ions and more. The DPST polarographic electrodes are especially constructed for extremely small or even no mercury consumption. Mercury or more electropositive analytes can be deposited on a pure carbon or gold surface. The DPST polarographic electrodes are designed for application in Metrohm, PolaroSensors, Gamma Analysen Technik, PAR and Ekom PA stands or any instrumentation with a suitable measuring cell.
Polarographic Electrodes - Product PDF (94 KB)
Platinum Electrodes
Platinum Electrodes - Product PDF (44 KB)
Conductivity Cells and Redox Electrodes
DPST Redox Electrodes
Conductivity and redox electrodes are noble metal (Gold or platinum) sensors for the measurement of conductivity and redox potential in many electrolytes and solutions. The DPST conductivity cells and redox electrodes are applicable to all commonly used electrochemical instruments.
Conductivity Cells - Product PDF (87 KB)
Redox Electrodes - Product PDF (59 KB)
Dissolved Oxygen Electrodes
Dissolved oxygen electrodes are amperometric sensors for the determination of oxygen in aqueous samples. DPST dissolved oxygen electrodes are applicable to all commonly used oxymeters in research, education and process control.
Dissolved Oxygen Electrodes - Product PDF (39 KB)
IJ (Intermediate Junction) and IH Electrodes
DPST IJ (Intermediate Junction)
ionode box IH40
Intermediate Junction from Ionode complements our standard pH electrode program. It is a remarkably versatile and durable reference electrode.
IJ (Intermediate Junction) and IJ Electrodes - Product PDF (192 KB)
SI 20 SCREW-IN pH combination
DPST SI 20
DPST SI 20
CS 41 Combined Sensor
pH, ORP, REFERENCE, Earth Electrode
DPST CS 41
DPST CS 41
Temperature Sensors
Many DPST-Sensors are equipped with integrated temperature sensors. The required type of the temperature sensor depends on the used instrumentation. Our offer includes Pt 100, Pt 1000, Ni 1 kΩ, Ni 2 kΩ and thermistor NR 3 kΩ temperature sensors according to your demand.
Temperature Sensors - Product PDF (65 KB)
Accessories and Auxiliary
Our DPST accessories and auxiliary program covers a large choice of calibration and testing solutions, ionic strength adjustors, buffer solutions, cleaning and storage solutions, reference and salt bridge solutions and other help- and needful chemical materials for analytical electrochemistry. DPST accessories and auxiliary are carefully harmonized with DPST electrochemical electrodes to obtain a long and optimal function. Of course DPST accessories and auxiliary fits to any commonly used electrochemical analytical tool.
Reference and Salt Bridge Solutions
Reference and Salt Bridge Solutions - Product PDF (44 KB)
Ion Standards
Ion Standards - Product PDF (45 KB)
Ionic Strength Adjustors, pH Adjustors, TISAB
Ionic Strength Adjustors, pH Adjustors, TISAB - Product PDF (44 KB)
Buffer Solutions
DPST Buffer Solution
Buffer Solutions - Product PDF (42 KB)
Heavy Metal Standards
Heavy Metal Standards - Product PDF (36 KB)
Conductivity Standards
Conductivity Standards - Product PDF (38 KB)
Redox Standards
Redox Standards - Product PDF (38 KB)
Storage and Cleaning Solutions
Storage and Cleaning Solutions - Product PDF (39 KB)
Connecting Cables
DPST Connecting Cables
Our large choice of connectors and the variable cable length makes the DPST electrochemical electrodes compatible to nearly every purpose and instrumentation. For the available connectors see chapter “Type numbers”. DPST standard sensors are equipped with a 1 m low-noise coaxial cable with BNC connector. The use of the special low-noise coaxial cable allows a cable length up to 10 m, what we offer on request.
Connecting Cables - Product PDF (39 KB)
ELMETRON Meters
Instrumentation as pH meters, ion meters, oxymeters, conductometers and multifunction meters we offer on request. Our DPST-ELMETRON meters are the optimal complement for precise and reliable measurements with DPST electrochemical electrodes as well as for general purpose. DPST-ELMETRON meters are available for every purpose, e.g. as robust and reliable easy to handle pocket instrument or as computerized intelligent high-end laboratory equipment. DPST-ELMETRON meters will convince you by an excellent cost-performance ratio and by their optimal functionality.
ELMETRON Meters - Product PDF (73 KB)
Declaration of Type Numbers
The comprehensive offer of DPST electrochemical analytical tools is characterized by systematic alphanumeric type numbers: The letters and the first numbers before the “-“ are specific for the particular sensor. The meaning is explained briefly in the concerning chapter. The „+“ at the end of the Type numbers is a placeholder for the connector type:
- 1 cable with banana or without any connector, for clamping
- 2 cable with BNC connector
- 5 cable with SN6 connector
- 6 SN6 or S7 head connector
- 7 cable with DIN connector
- 8 cable with CINCH connector
- 0 cable with SMS connector
[To view a file in PDF format, you need Adobe Acrobat Reader, which is a free application distributed by Adobe Systems.]